» Products » Cryog

Cryog

Water-repellent cryogenic leather glove

Colour

Straw-coloured

Size

10

The product complies with the European Directive 89/686, notably regarding ergonomics, innocuousness, comfort and with standards :

WATER-REPELLENT CRYOGENIC LEATHER GLOVE

Water-repellent cowhide full grain leather. Aluminized polyester insert. Cowhide split leather cuff. Hand and cuff in synthetic. American assembly. 20 cm cuff. Length: 40 cm.

Water-repellent cowhide full grain leather (TECHNICUIR). Thickness 1,10 to 1,30 cm.

Aluminised insert.

Synthetic lining.

Cowhide split leather cuff.

Kevlar® thread seams.

15/02/16

  • Heavy industry
  • Cold / Weather
  • Wearing
  • Adhesive tape :
    • Quick fitting and removal
    Conform to MR019
    Tested to Nitrogen Gas

    Aluminised polyester:
    • Thermal protection

    Water-repellent treatment:
    • Resistance to water penetration
    • Better abrasion
    • More comfort and flexibility

    Reference pcb Colour Size
    CRYOG10 36 Straw-coloured 10
  • EN420:2003 General requirements
    • 5 Dexterity (from 1 to 5)
    • Conform to harmlessness (pH, chrome VI levels, etc…). • Conform to the size charts (see chart on below). • Pass the dexterity test. • Conform to the labelling, information and identification instructions.
  • EN388:2003 Protective gloves against mechanical Risks (Levels obtained on the palm)
    • 2 Resistance to abrasion (from 1 to 4)
    • 2 Resistance to cutting (from 1 to 5)
    • 2 Resistance to tear (from 1 to 4)
    • 2 Resistance to puncture (1 to 4)
    The EN388 standard applies to all types of protective gloves with respect to physical and mechanical aggression from abrasion, cutting from slicing, perforation and tearing. ABRASION RESISTANCE (1 à 4): Number of cycles required to damage the sample at constant speed. RESISTANCE TO CUTTING WITH A BLADE (1 à 5): Number of cycles required to cut the sample at constant speed. RESISTANCE TO TEARING (1 à 4): Maximum force required to tear the sample. RESISTANCE TO PERFORATION (1 à 4): Force required to pierce the sample with a standardized punch.
  • EN511:1994 Protective gloves against cold (X = Unrealized test)
    • 2 Resistance to convective cold (from 1 to 4)
    • 2 Resistance to contact cold (from 1 to 4)
    • 1 Waterproof (0 or 1)
    The EN511 standard defines the requirements and test methods for cold protection gloves from cold transmitted by convection or conduction down to -30°C. This cold can be from climatic conditions or industrial activity. – Resistance to convective cold: 1 to 4. – Resistance to contact cold: 1 to 4. – Impermeability to water: 1 to 1.
  • EN420:2003+A1:2009 4.2 Glove - Resistance to water penetration
    • 4/4 ≥ 180 mn Level of performance - Time of penetration