The product complies with the European Directive 89/686, notably regarding ergonomics, innocuousness, comfort and with standards :
NEOPRENE GLOVE – LENGTH 38 CM
Neoprene on cotton knitted lining gauge 10. Length: 38 cm. Thickness 1,40 mm.
Tested according to EN374-3:2003 determination of permeation resistance, levels of permeation from 1 to 6 (K : Sodium hydroxyde 40% (NaOH ) = 6/6, L: sulphuric acid (96%) =4/6, J : n-Heptane = 2/6).
Support: gauge 10 cotton.
Coating: Neoprene. Foam finishing.
14/09/15
Construction / Civil engineering
Heavy industry
Mining
Oil / Gas
Biological chemical particles
Heat
Wearing
Reference
pcb
Colour
Size
VE511NO09
60
Black
9/10
VE511NO10
60
Black
10/11
EN420:2003+A1:2009 General requirements
5Dexterity (from 1 to 5)
• Conform to harmlessness (pH, chrome VI levels, etc…).
• Conform to the size charts (see chart on below).
• Pass the dexterity test.
• Conform to the labelling, information and identification instructions.
EN388:2003 Protective gloves against mechanical Risks (Levels obtained on the palm)
2Resistance to abrasion (from 1 to 4)
1Resistance to cutting (from 1 to 5)
3Resistance to tear (from 1 to 4)
2Resistance to puncture (1 to 4)
The EN388 standard applies to all types of protective gloves with respect to physical and mechanical aggression from abrasion, cutting from slicing, perforation and tearing.
ABRASION RESISTANCE (1 à 4): Number of cycles required to damage the sample at constant speed.
RESISTANCE TO CUTTING WITH A BLADE (1 à 5): Number of cycles required to cut the sample at constant speed.
RESISTANCE TO TEARING (1 à 4): Maximum force required to tear the sample.
RESISTANCE TO PERFORATION (1 à 4): Force required to pierce the sample with a standardized punch.
EN374-2:2003 Protective gloves against chemicals and micro-organisms - Part 2: Determination of resistance to penetration
Resistant gloves to micro-organisms (bacteria, mushrooms), tested according to EN374-2
Penetration (tested as per standard EN374-2):
Diffusion, at a non molecular scale, of a chemical product and/or micro-organism through the porosities, seams, micro-holes or other imperfections present in the material of the protective glove.
EN374-3:2003 Protective gloves against chemicals and micro-organisms - Part 3: Determination of resistance to permeation by chemicals
J K LResistant gloves to permeation by chemicals, tested according to EN374-3
Méthanol (A) CAS 67-56-1
Acetone (B) CAS 67-64-1
Acetonitrile (C) CAS 75-05-8
Dichloromethane (D) CAS 75-09-2
Carbon disulfide (E) CAS 75-15-0
Toluene (F) CAS 108-88-3
Diethylamine (G) CAS109-89-7
Tetrahydrofuran (H) CAS 109-99-9
Ethyl acetate (I) CAS 141-78-6
2 > 30 mnn-Heptane (J) CAS 142-85-5
6 > 480 mnCaustic soda 40% (K) CAS 1310-73-2
4 > 120 mnSulphuric acid 96 % (L ) CAS 7664-93-9
Permeation (tested as per standard EN374-3):
Process by which a chemical product diffuses through the material of a protective glove, at the molecular scale. A glove is considered resistant to chemical products if it obtains a performance index to permeation at least equal to 2 for three test chemical products included in the following list of chemical products: